Search results for "magnetic [charge]"
showing 10 items of 6136 documents
Cardiovascular magnetic resonance-derived aortic compliance, distensibility and pulse wave velocity at rest and during a supine bicycle exercise in y…
2014
Background Purpose: Risk of aortic rupture is evaluated based on the vessel diameter; this parameter is probably insufficient. In vivo evaluation of biomechanical property of the aortic tissue might be of interest to discriminate between normal and altered aortic tissue (A Lalande et al, JMRI 2008). The purpose of this study was to describe a technique to measure regional aortic compliance (AC), aortic distensibility (AD) and aortic stiffness with 1.5 T MRI in young individuals under resting conditions and during supine bicycle exercise.
Beurteilung der Durchgängigkeit von koronaren Bypassgefäßen mit einer 2D T2-gewichteten Turbo-Spin-Echo-Sequenz (HASTE) in Atemanhaltetechnik
1999
AIM To evaluate the patency of coronary artery bypass grafts with a 2D T2-weighted breath-hold turbo-spin-echo sequence. METHODS 38 patients with 97 grafts (19 internal mammary artery and 78 saphenous vein grafts) and a total of 120 distal anastomoses were studied at 1.5 Tesla in supine position using a phased array body coil. An ECG gated 2D T2-weighted breath-hold turbo-spin-echo sequence (HASTE) was performed. Reference method was selective coronary angiography. The image material was evaluated independently by two radiologists (observer one, a radiological fellow and the second a staff radiologist). RESULTS Observer 1 reached a sensitivity of 96% (72/75) and a specificity of 91% (20/22)…
A regenerative 3D scaffold for inguinal hernia repair. MR imaging and histological cross evidence. Qualitative study
2021
Abstract Background Inguinal hernia is a degenerative disease occurring in a high motile surround. Stopping degeneration and promoting tissue regeneration should be the treatment goal. Groin hernias are conventionally managed with static flat meshes, mostly fixated to the delicate inguinal environment. Far from a regenerative effect, the biologic response of conventional hernia meshes is characterized by a foreign body reaction leading to a stiff/shrunken scar plate, which is often the source of unpleasant complications. Recently, a newly engineered 3D device for inguinal hernia repair – ProFlor-has been developed to produce a regenerative biological response. Unlike conventional hernia mes…
Microvascular obstruction in the right ventricle in reperfused anterior myocardial infarction. Macroscopic and pathologic evidence in a swine model.
2013
article i nfo Introduction: Data on right ventricular (RV) involvement in anterior myocardial infarction are scarce. The presence of RV microvascular obstruction (MVO) in this context has not been analyzed yet. The aim of the present study was to characterize the presence of MVO in the RV in a controlled experimental swine model of reperfused anterior myocardial infarction. Materials and Methods: Left anterior descending (LAD) artery-perfused area (thioflavin-S staining after selective infusioninLADartery),infarctsize(lackof triphenyltetrazolium-chloride staining) andMVO (lack of thioflavin-S staininginthe core oftheinfarctedarea) inthe RVwere studied.A quantitative(%of theventricularvolume…
Magnetic resonance microscopy and correlative histopathology of the infarcted heart
2019
Altres ajuts:The present study was supported by the EU Joint Programming Initiative 'A Healthy Diet for a Healthy Life' (JPI HDHL INTIMIC-085), Generalitat Valenciana (GV/2018/116), INCLIVA and Universitat de Valencia (program VLC-BIOCLINIC 20-nanomIRM-2016A). Delayed enhancement cardiovascular magnetic resonance (MR) is the gold-standard for non-invasive assessment after myocardial infarction (MI). MR microscopy (MRM) provides a level of detail comparable to the macro objective of light microscopy. We used MRM and correlative histopathology to identify infarct and remote tissue in contrast agent-free multi-sequence MRM in swine MI hearts. One control group (n = 3 swine) and two experimenta…
Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes.
2000
Detection and characterization of intraorbital foreign bodies (IFB) is fundamental in acute trauma setting, preventing inflammatory sequelae or complications related to IFB movements when a MRI study is planned. Papers concerning plain film and CT sensibility in IFB detection show controversial results. For this reason we investigated plain film, CT and MRI sensibility in the evaluation of IFB. For an in vitro model, specimens of dry and fresh wood, glass, iron, plastic and graphite were immersed in animal lard and in a 0.9 % sodium chloride plus 3.5 g/dl human serum albumin solution. Specimens of different size and nature where also implanted into enucleated pig eyes. Air bubbles were intr…
Efficient 3D Deep Learning for Myocardial Diseases Segmentation
2021
Automated myocardial segmentation from late gadolinium enhancement magnetic resonance images (LGE-MRI) is a critical step in the diagnosis of cardiac pathologies such as ischemia and myocardial infarction. This paper proposes a deep learning framework for improved myocardial diseases segmentation. In the first step, we build an encoder-decoder segmentation network that generates myocardium and cavity segmentations from the whole volume, followed by a 3D U-Net based on Shape prior to identifying myocardial infarction and myocardium ventricular obstruction (MVO) segmentations from the encoder-decoder prediction. The proposed network achieves good segmentation performance, as computed by avera…
Imaging of inner ear malformations: a primer for radiologists
2021
AbstractIn the multidisciplinary management of patients with inner ear malformations (IEMs), the correct diagnosis makes the differences in terms of clinical and surgical treatment. The complex anatomical landscape of the inner ear, comprising several small structures, makes imaging of this region particularly challenging for general radiologists. Imaging techniques are important for identifying the presence and defining the type of IEM and the cochlear nerve condition. High-resolution magnetic resonance imaging (MRI) sequences and high-resolution computed tomography (HRCT) are the mainstay imaging techniques in this area. Dedicated MRI and HRCT protocols play an important role in the diagn…
Imaging of hepatocellular carcinoma: a pilot international survey
2020
Purpose To perform an international survey on current practices in imaging-based surveillance, diagnosis, staging, and assessment of treatment response for HCC. Materials and methods Three themes were covered in this international survey: demographics of respondents and liver imaging expertise; imaging practices for screening, surveillance, diagnosis, staging, and assessment of treatment response for HCC; and diagnostic imaging systems used. Descriptive summaries were created. Results Of 151 respondents, 22.5% were from Asia, 6.0% from Europe, 19.9% from North America, 26.5% from South America, and 25.2% from Australasia; 57.0% respondents worked in academic and 34.4% in private or mixed se…
Diagnosis and definition of biventricular non-compaction associated to Ebstein's anomaly
2011
Abstract Background Non-compaction of ventricular myocardium is a rare congenital cardiomyopathy characterized by the presence of an extremely thickened endocardial layer with prominent trabeculations and deep recesses in communication with ventricular chamber and determining the typical spongeous aspect. The diagnosis of non-compaction of ventricular myocardium is possible through the identification of morphological alterations by echocardiographic evaluation. Ebstein's anomaly is a rare congenital cardiac disease, defined as the significant apical displacement of the part of the tricuspid valve causing significant tricuspid regurgitation and reduction of the functional right ventricle, ri…